News

 

2016-11-02

First part of the Conductance Profile Measurement project completed

The first part of the project with Conductance Profile Measurement in Hyltebruk (in Sweden) has now ended and we are preparing ourselves for the next step. The CPM system (Conductance Profile Measurement) has 10 measuring points for both temperature and electrical conductivity.

The pictures below show the 10 measuring points retracted into a segment and a typical appearance of the measured profile. The results show that there is a possibility of steering where the pulp devolves from having a low electrical resistance (liquid phase) to a high electrical resistance (steam phase). We have seen that the vaporization point can be steered with the help of the amount of added dilution water.

CPMCPM

 

 

 

 

 

 

E-mail: This email address is being protected from spambots. You need JavaScript enabled to view it.  Phone: +46 (0)8-556 477 00  Copyright © 2012-2020 Dametric

Microsoft Certificate